> CAEN > Electronic Instrumentation > Products > Power Supplies > EASY3000 HV & LV Multichannel System for Hostile Area > EASY3000 AC/DCs Conventers > A3486 Login | Register
EASY3000 HV & LV Multichannel System for Hostile Area - A3486
3-phase 220/400 Vac – 48 Vdc (2 ch x 2 kW/1 ch x 4 kW) Converter Obsolete product 

Highlights
  • 3U 19” Euro Rack, 50 cm deep
  • Dual 2 kW or Single 4 kW 48V output
  • 48V ± 10% output dynamics (remotely programmable)
  • 40 A maximum programmable output current (per channel)
  • Overcurrent protection (programmable trip time)
  • Overcurrent, Undervoltage and Overvoltage status remotely available
  • Voltage ripple smaller than 100 mV rms
  • Local or remote inhibit function
  • Vertical “bottom-to-top” forced air cooling
  • EASY-class magnetic field and radiation tolerance
Products
Power Supplies
EASY3000 HV & LV Multichannel System for Hostile Area
EASY3000 AC/DCs Conventers
A3486 - 3-phase 220/400 Vac – 48 Vdc (2 ch x 2 kW/1 ch x 4 kW) Converter
Evaluation of contents:
What do you think about the page contents usefulness?

1 2 3 4 5
mediocre excellent
 

The CAEN Mod. A3486 is a two channel 400 Vac – 48 Vdc converter, which allows to integrate into the EASY channels control also the management of the 48 V power supplies. Each channel provides a 2 kW output (referred to earth) and can be tracked in order to obtain one 4 kW output. This module is designed to work as main converter in LHC hostile areas, thus completing the EASY system. Features include local or remote control, overload protection and local or remote inhibit function.
The module front panel houses LEDs and channels monitor signals. The channel outputs are provided through Anderson Power single pin connectors.
Mod. A3486S, with power supply and link connection on the front panel, is also available.



Packaging 19"-wide, 3U-high Euro-mechanics rack;Depth: 50 cm.
Voltage 44 ÷ 52 V adjustable via software
Output Polarity Positive; common floating ground DC insulation vs. Earth >4KOHm; max Vcm (common mode) : ±10 V
Max. Output Power 4 kW
Voltage Ripple <100mVpp measured on 10Hz to 20MHz bandwidth
AC input 3-phase 400 V / 50 Hz
DC input 2A @ 48V (see label below) 2A @ 48V
Voltage Monitor vs. Output Voltage Accuracy: max. ±0.5%
Voltage Set vs. Output Voltage Accuracy: max. ±0.5%
Current Monitor vs. Output Current Accuracy: ± 1A ± 2% of reading
Current Set vs. Output Current Accuracy: ± 1A ± 2% of setting

Description Last Update
A3000NF_REV1.pdf 24.04.2007
A3486_REV12.pdf 10.12.2007
Precautions_for_Handling_Storage.pdf 04.01.2008

Name Last Update
A3486 Firmware 21.10.2008
A3486 User Manual 25.09.2007

     Compare with other  EASY3000 AC/DCs Conventers
  Model Package Function Description Compare
All / Reset
  A3484 EASY3000 HV & LV Multichannel System for Hostile Area EASY3000 AC/DCs Conventers 3-phase 220/400 Vac – 48 Vdc (1 ch x 2.5 kW) Converter
  A3485 EASY3000 HV & LV Multichannel System for Hostile Area EASY3000 AC/DCs Conventers 3-phase 400 Vac – 48 Vdc (2 ch x 2.5 kW) Converter
         
Code Description
WK3486XAAAAA K3486 - Anderson Power and AMP connectors for 5 A3486 
WA3486XAAAAA A3486 - 3-phase 220/400 Vac - 48 Vdc(2 ch x 2 kW/1 ch x 4 kW) Converter - APP Conn. 
WA3486BXAAAA A3486B - 3-phase 220/400 Vac - 48 Vdc(2 ch x 2 kW/1 ch x 4 kW) Converter - Bolt Conn. 
WA3486SXAAAA A3486S - 3-phase 220/400 Vac - 48 Vdc(2 ch x 2 kW/1 ch x 4 kW) Converter - Frontal Acc 
WA3000NFXAAA A3000NF - 3 Phase Notch Filter for a A3486(no H.E.) 